OM_RAD-4_Rad-13-Receive

This tests the RAD-4 (Procedure Scheduled) and RAD-13 (Procedure Updated) transactions from the point of view of the Image Manager as system under test.

In this test, we will check that your Image Manager is able to integrate the scheduling and cancelllation of procedures received from the Order Manager tool playing the role of the Order Filler actor. 

You may use the Order Manager to send

  • RAD-4 and RAD-13:  HL7 v2.3.1 orders (SWF), or
  • RAD-4 and RAD-13:  HL7 v2.5.1 orders (SWF.b)

Prerequisite

  1. CONFIGURATION: Before beginning this test, do not forget to check that the configuration (IP address, port, application/facility names) of your system under test is entered within the Order Manager tool.  Use the "SUT Configurations" menu. 
  2. TEST PATIENT:   In the steps below, you will use a test patient to create and schedule an order in the Order Manager.  Follow these  instructions for using Patient Manager to create a patient that is then used by the Order Manager.

Refer to the Order Manager user manual.

Test Steps

As a receiver in this test, your Image Manager shall be able to integrate all of the message structures defined in the technical framework. As a consequence, you are asked to perform these four steps.

1. Procedure Scheduled [RAD-4]

In this step, your Image Manager proves its ability to accept and integrate a new scheduled procedure sent by the Order Filler.

  1. Go to menu 'Radiology' or 'Eye care', then --> Order Filler --> [RAD-4/13] Schedule/update procedures
  2. Select your system under test in the drop-down list
  3. Select "Procedure Scheduled" as action to perform.  
  • By default, you will get an HL7 v2.3.1 ORM.  If you want an HL7 v2.5.1 OMG messages, click that box.
  • Select an existing order in the tool, or create an order from scratch
  • Complete the "Scheduled Procedure Step" information and then select the "Send message" button
  • Retrieve the permanent link to the test report and paste it into Gazelle Test Management as the results for this test.
  • Take a screenshot of your application as a proof of the good integration of the message (eg. this may be evidence of a database entry). Upload it in Gazelle.
  • 2. Procedure update:  cancel order request (CA) [RAD-13]

    In this step, your Order Image Manager proves its ability to accept and integrate an order cancellation sent by the Order Filler (ORC-1="CA") and to acknowledge it.

    1. Go to menu 'Radiology' or 'Eye care', then --> Order Filler --> [RAD-4/13] Schedule/update procedures
    2. Select your system under test in the drop-down list
    3. Select "Procedure update: cancel order request" as action to perform.  
      1. By default, you will get an HL7 v2.3.1 ORM.  If you want an HL7 v2.5.1 OMI message, click that box. 
    4. Select the procedure to cancel and when the pop-up raises, click on the "Yes" button.
    5. Retrieve the permanent link to the test report and paste it in Gazelle.
    6. Take a screenshot of your application as a proof of the good integration of the message. Upload it in Gazelle.

    3. Procedure update: discontinue order request (DC) [RAD-13]

    In this step, your Image Manager proves its ability to accept the discontinue of an ongoing order sent by the Order Filler (ORC-1="DC") and to acknowledge it.

    1. Go to menu 'Radiology' or 'Eye care', then --> Order Filler --> [RAD-4/13] Schedule/update procedures
    2. Select your system under test in the drop-down list
    3. Select "Procedure update: discontinue order request" as action to perform.  
      1. By default, you will get an HL7 v2.3.1 ORM.  If you want an HL7 v2.5.1 OMI message, click that box. 
    4. Select the procedure to cancel and when the pop-up raises, click on the "Yes" button.
    5. Retrieve the permanent link to the test report and paste it in Gazelle.
    6. Take a screenshot of your application as a proof of the good integration of the message. Upload it in Gazelle.

    4. Procedure update: change order request (XO) [RAD-13]

    In this step, your Image Manager proves its ability to accept the procedure update/change order request (order still scheduled or in progress) sent by the Order Filler (ORC-1="XO") and to acknowledge it.

    1. Go to menu 'Radiology' or 'Eye care', then --> Order Filler --> [RAD-4/13] Schedule/update procedures
    2. Select your system under test in the drop-down list
    3. Select "Procedure update: change order request" as action to perform.  
      1. By default, you will get an HL7 v2.3.1 ORM.  If you want an HL7 v2.5.1 OMI message, click that box. 
    4. Select the procedure to cancel and when the pop-up raises, click on the "Yes" button.
    5. Retrieve the permanent link to the test report and paste it in Gazelle.
    6. Take a screenshot of your application as a proof of the good integration of the message. Upload it in Gazelle.

    5. Procedure update: order has been completed (XO) [RAD-13]

    In this step, your Image Manager proves its ability to accept the procedure update/order completed sent by the Order Filler (ORC-1="XO") and to acknowledge it.

    1. Go to menu 'Radiology' or 'Eye care', then --> Order Filler --> [RAD-4/13] Schedule/update procedures
    2. Select your system under test in the drop-down list
    3. Select "Procedure update: order has been completed" as action to perform.  
      1. By default, you will get an HL7 v2.3.1 ORM.  If you want an HL7 v2.5.1 OMI message, click that box. 
    4. Select the procedure to cancel and when the pop-up raises, click on the "Yes" button.
    5. Retrieve the permanent link to the test report and paste it in Gazelle.
    6. Take a screenshot of your application as a proof of the good integration of the message. Upload it in Gazelle.

    Evaluation

    The permanent links to the test report & the screen shots demonstrate that you have successfully handled the received order messages.